How to calculate LED modules: pixels, power and weight without Excel tables

A simple way to size a screen at the early stage: pixels, power and weight, to check against the manufacturer's datasheet.

A 6 × 3 m screen made of 500 × 500 mm modules is 12 × 6 = 72 modules. At P2.6 each module has 192 × 192 px, so the screen runs at 2304 × 1152 px. The processor has to handle this resolution, and this is the resolution you set in the Resolume slice.

Calculate power with headroom: a P2.6 module draws 150 W on average and 450 W at peak. 72 modules means 10.8 kW on average, but you have to size the circuit protection for the peak, not for the average. A full white slide at the finale can catch a generator by surprise.

Weight determines the structure: 72 modules × 7.5 kg = 540 kg for the screen alone, plus the frame, plus the cabling. That dictates the truss cross-section and the number of rigging points.

StageDesigner calculates all of this while you design the screen: you see the pixels, power and weight on the screen card, and changing the module recalculates everything from scratch.