StageDesigner

Acoustics: SPL and STI maps in the scene

The Acoustics tab and the map switch in the top bar: SPL A, SPL per band, STI, difference to main and arrival time maps at ear height, results, intelligibility thresholds and notes with fixes.

4 min read
Documentation contents ▾

The Acoustics tab simulates the sound field at the listeners ear height and shows it as a semi-transparent map in the scene. Results recalculate in the background after changes to sets, angles, levels and room settings.

SoundAcoustics
STAGEdelay 18 msSPL 92104 dBSTI 0.62RT60 1.4 s
SPL map on the ear plane with isolines every 3 dB.

When the map is calculated

You need audience loudspeakers and a listening zone. Without loudspeakers the tab offers Design sound system (monitors are not part of the map). Without a zone it offers Open venue layout plan: the receiver points lie in the plan zones (tables, audience seating, dance floor, chillout zones), excluding the stage and the control room. When there is no plan, the app assumes a substitute zone (for example the room floor or the area in front of the stage) and says so in the results.

The point grid has a 0.5 m step, and a larger one for big zones (at most 20,000 points). While you move sets the result is approximate, which is indicated by the line "Approximate result while moving".

Map in the scene

Show map in scene
Turns on the map. The loudspeaker icon button in the top bar (Show acoustics map) does the same; it is active when the project has a sound system.
Quantity
SPL A (LAeq at the target level), SPL per band (level in an octave band), STI (speech intelligibility), Difference to main (arrival time of the dominant set relative to main), Arrival time (the first significant arrival of direct sound).
Band
For SPL per band: octave bands from 63 Hz to 8 kHz.
Isolines every 3 dB
For SPL maps.
Array element axes
Element axis lines down to where they cross the ear plane.
Scale
Map color legend.

Results

TileMeaning
Avg STIAverage STI in the zone, with the minimum
SPL ARange of levels in the zone and the average, relative to the target
UniformityHalf of the 10–90 % level spread in the zone; target ±3 dB
T 500–1000 HzReverberation time (indoors)
Max LAeqThe highest LAeq in the zone relative to the 100 dB(A) guideline
Min STIThe lowest STI in the zone

Below the tiles: Level headroom (how many dB are missing to full drive), LAeq at FOH (with the time after which the NDN reference value of 85 dB(A) for 8 h is reached at the FOH position) and Listeners.

STIRating in the app
≥ 0.75excellent
0.60–0.74good
0.45–0.59fair
0.30–0.44poor
< 0.30bad

Notes and fixes

The list of notes shows problems with a one-click fix button. When everything is fine, you see "No notes: level, coverage, reverberation and delays are fine."

NoteFix
The system does not reach the target levelChange the system or the target
Not enough level in the rear partAdd delay tower
Not enough level in part of the zoneSet angles
Uneven coverageSet angles
Too loud near the stageReduce level or Set angles
Long reverberationChange materials (heavy drape on the walls)
Low intelligibility (outdoor)Background noise too close to the speech level
Delay: set nameSet delay
Exposure at the control roomInformation relative to NDN 85 dB(A)

The Acoustics report button opens the project report at the acoustics section. See Sound and acoustics report.

Method in brief

The direct field is calculated in octave bands 63 Hz–8 kHz from the loudspeaker class directivity, the inverse square law and air absorption per PN-ISO 9613-1. Sets add up energetically; subs at 63 and 125 Hz can add up with phase (the Subs: phase summation at 63 and 125 Hz switch). The app determines STI with the prediction method per IEC 60268-16 from the reverberation time, the direct-to-reverberant energy ratio and the signal-to-noise ratio. The operating level is chosen so that the median LAeq in the zone equals the target level.

Did not find the answer?
Describe the problem and we will reply with a solution or add an article.