StageDesigner

Control room wizard

A four-step wizard picks equipment for the event type, sets the tables on a riser on the stage axis, and connects the devices with cables right away.

6 min read
Documentation contents ▾

In StageDesigner a control room is the complete package: tables with devices, a riser, stools, racks, a barrier, plus the connections between devices and the cables to the stage. The wizard builds all of it from a few decisions. Every field has a default taken from the project, so you can place the control room after the first step and refine it later.

How to open the wizard

ProjectControl room…

When the project has no control room yet, the command opens the wizard. When it has one, it opens the Control room panel, where the Create another control room… button starts the wizard for the next position. You edit an existing control room in the wizard with Edit in wizard… from the card menu in the panel or from the inspector.

Lighting console4 universesDMX nodeArt-Net → 4 linesDigital mixer48 ch · DanteStagebox32 / 16Media server2 × 4KLED processor10 portsIntercom base5 + 2 beltpacksLine 1 · 12 fixturesLine 2 · 8 fixturesLine 3 · 6 fixturesLine 4 · 6 fixturesstage · 40 mLED screen
The control room brings together the lighting, sound, and video positions with intercom and power.

Step 1: Event type

Pick one of four tiles. The tile guessed from the project carries the Suggested from project badge. Changing the type loads its default set, options, number of table rows, and audience type.

TypeDescription in the wizardOptions on by defaultRecommended distance from the stage
ConferenceSpeakers, presentations, and speech reinforcement; 100–500 people.Recording or streaming8–20 m
GalaTables, a stage with a host, cameras on screens; 200–800 people.Recording, cameras on screens (IMAG)10–25 m
ConcertStanding audience, large lighting and video system; 1000 people and up.Recording, IMAG, backup console, barrier15–30 m
Trade fairA booth or small stage: a simple controller, a laptop, and one screen.None2–10 m

Below the tiles, the Project data group shows what the wizard read from the scene: Number of people (from the venue layout plan, chairs, or the people simulation), the audience type (Seated or Standing), LED screens with total pixels and data ports, and fixtures with the number of DMX channels and universes. You can override the number of people; the Auto badge and the reset button bring back the value from the project.

The Options group has four switches: Recording or streaming, Cameras on screens (IMAG), Backup console, and Barrier around the control room. Each option turns its related devices on and off, for example PTZ cameras with a controller for IMAG, or a recorder for recording.

Step 2: Equipment

The device list is split into the Lighting, Video, and Sound sections plus a collapsed Network, power, intercom section. Each row has a switch (device in the set or not), the function name, the model from the catalog, the quantity, and a line with dimensions, weight, power, and ports.

What the default sets contain

Conference
Lighting console and a DMX node at the stage; video switcher, two presentation laptops, HDMI ↔ SDI converters, LED processor, preview monitors, a video confidence monitor, and a speaker timer; audio mixer, stagebox, microphone receiver, and playback; switch, wireless intercom with an antenna and three beltpacks, UPS, and power strips.
Gala
A larger console with an onPC backup laptop and two nodes, two media servers, PTZ cameras with a controller (IMAG), PGM and multiview monitors, recorders and a streaming encoder, an audio mixer with a 32-channel stagebox, two receivers, intercom with five beltpacks, two UPS units, and a control room distribution board.
Concert
A console with a backup console, a 12-port DMX node at the stage and nodes on the trusses, a DMX splitter, media servers in a rack, a presentation processor and operated cameras (IMAG), an LED processor with a data distributor, a multiview TV, an audio mixer with two stageboxes, two switches, intercom with six beltpacks, UPS units, and a distribution board.
Trade fair
An onPC wing with a lighting laptop, a playback laptop, LED processor, preview monitor, audio mixer, microphone receiver, switch, UPS, and a power strip.

For some devices the model list starts with alternatives. For wireless intercom the alternative is wired intercom (partyline) with cabled beltpacks, a good fit for fixed positions and smaller productions.

Automatic capacity sizing

The automation matches the model or quantity to the project and marks the row with the Sized badge plus a hint explaining where the number came from. The rules:

  • LED processor from the total pixels and ports of the screens, with at least one spare port;
  • DMX nodes from the number of universes, with one free output;
  • stagebox from the number of inputs plus 25%;
  • switch from the number of network devices plus 25%;
  • UPS from the power of critical devices, loaded to no more than 80%;
  • a 32 A 3-phase distribution board when the control room draws more than 2.9 kW;
  • power strips when outlets are missing, and console monitors according to the number of its outputs.

Below the list, the Weight, Max power, Tables, and Rack tiles total the set live. You do not add tables, the riser, stools, or racks by hand: the layout in step 3 picks them.

Step 3: Layout

Settings on the left; on the right a mini floor plan of the control room and readouts: distance from the stage, sound delay, and footprint. In the Tables and riser group you choose the number of table rows and the riser height; in the Position group, the placement method and distance. Details in the articles Tables, riser, and barrier and Position, direction, and zone on the plan.

Step 4: Summary

The tiles show the weight (with furniture and riser), maximum and typical power, and the number, length, and weight of cables. Below are the warnings with fix buttons, the Control room group with readouts, and the Apply group:

Control room name
The name shown in the panel, inspector, diagram, and report.
Route cables to the stage automatically
In addition to the connections inside the control room, cables to devices at the stage are created. When this service is unavailable, you can plan the stage cables later in the Cabling panel.
Add an exclusion zone in the venue layout plan
A "Control room" zone is created on the plan, which tables and audience seating avoid. Active only when the project has a venue layout plan.

Applying and undoing

The Apply to scene button is available at every step (when editing: Apply changes to scene). The wizard preview is calculated by the same function as the apply step, so the numbers and warnings in the wizard match what lands in the scene. The whole operation is one undo step. On the last step, Show connection diagram opens a preview of the diagram before you apply.

The footer shows the number of errors and notices in the preview; clicking it jumps to the list in the summary. The Layout and Summary steps have a notice counter, so you can see where a decision is needed.

Did not find the answer?
Describe the problem and we will reply with a solution or add an article.