The control room analysis is a single source of numbers for the wizard, panel, inspector, and project report. It calculates the distance from the stage, sound delay, riser, number of tables, weight, power, and UPS load, then reports warnings at three levels: error, warning, and info.
Where you see warnings
- in the wizard: the counter in the footer and next to the
LayoutandSummarysteps, the full list in the summary; - in the
Control roompanel: the list below the card tiles; - in the control room inspector: the
Warningssection.
Position and safety
| Situation | Level | Fix |
|---|---|---|
| Control room farther than the recommended range | warning or info | Move closer |
| Control room closer than the recommended range | warning | Move farther |
| Sound position off the stage axis | warning or info | Center on stage axis |
| Direction more than 60° from the direction toward the stage | info | Turn toward stage |
| Riser lower than recommended | warning | Set … m |
| Riser from 0.6 m without a barrier | warning | Add barrier |
| Control room closer than 1.5 m to an exit | error | Move |
| Control room on an escape route | error | Move off the route |
| Control room in a main aisle or circulation route | warning | Move out of the aisle |
| Control room on the dance floor | warning | Move off the dance floor |
| Control room overlaps scene objects | warning | Show control room |
| PTZ camera lens too low, behind the operators’ heads | warning | Put on tripod |
When there is no free space on the stage axis outside aisles, zones, and objects, the distance or axis warning becomes info: you then know the mix will be heard from the side or from farther away, and you need to account for that when tuning the system.
Ports, outlets, and signal
| Situation | Fix |
|---|---|
| A device has no input for the source signal (e.g. HDMI to SDI) | Add converter … → … |
| The switch has no free port for the stagebox | Add switch |
| Not enough power outlets in the control room | Add power strip (or several strips) |
| Some critical devices are not on a UPS | Add power strip after the UPS |
| Monitor, recorder, encoder, or LED processor without a video signal | Show in diagram or Add HDMI splitter |
| No backup connection processor → screen | Change processor |
| Monitor on stage fed over HDMI AOC | Add converter at monitor |
| A control room connection without a cable (e.g. deleted by hand) | Reconnect |
| DMX fixtures in the scene but no console in the control room | Add lighting console |
Info items without a button suggest technical solutions: LED data over copper on a run longer than about 70 m (the limit is 100 m) is better sent over fiber with a converter at the screen, and microphone receivers more than 30 m from the stage call for remote antennas at the stage.
Weight, power, and supply
Put on a frame stand: the console or the total of devices exceeds the load capacity of a folding table.Pick a larger UPS: the UPS is loaded above 80%.Add 32 A 3-phase distribution board: the control room draw exceeds a 16 A outlet (2.9 kW with margin).- The switch PoE budget is smaller than the draw of the powered devices: add a PoE switch or PoE injectors.
Devices without a control room
After you delete only the footprint (Delete footprint, keep devices…), the devices go to the Devices without a control room group in the panel. The Rebuild control room button creates a new footprint around them facing the stage, and reassigns the devices and cables to it.