StageDesigner

Analysis and fixes

The analysis checks the control room’s position, riser, ports, outlets, power, and connections. Most notices have a fix button that makes the correction as one undo step.

4 min read
Documentation contents ▾

The control room analysis is a single source of numbers for the wizard, panel, inspector, and project report. It calculates the distance from the stage, sound delay, riser, number of tables, weight, power, and UPS load, then reports warnings at three levels: error, warning, and info.

Where you see warnings

  • in the wizard: the counter in the footer and next to the Layout and Summary steps, the full list in the summary;
  • in the Control room panel: the list below the card tiles;
  • in the control room inspector: the Warnings section.

Position and safety

SituationLevelFix
Control room farther than the recommended rangewarning or infoMove closer
Control room closer than the recommended rangewarningMove farther
Sound position off the stage axiswarning or infoCenter on stage axis
Direction more than 60° from the direction toward the stageinfoTurn toward stage
Riser lower than recommendedwarningSet … m
Riser from 0.6 m without a barrierwarningAdd barrier
Control room closer than 1.5 m to an exiterrorMove
Control room on an escape routeerrorMove off the route
Control room in a main aisle or circulation routewarningMove out of the aisle
Control room on the dance floorwarningMove off the dance floor
Control room overlaps scene objectswarningShow control room
PTZ camera lens too low, behind the operators’ headswarningPut on tripod

When there is no free space on the stage axis outside aisles, zones, and objects, the distance or axis warning becomes info: you then know the mix will be heard from the side or from farther away, and you need to account for that when tuning the system.

Ports, outlets, and signal

SituationFix
A device has no input for the source signal (e.g. HDMI to SDI)Add converter … → …
The switch has no free port for the stageboxAdd switch
Not enough power outlets in the control roomAdd power strip (or several strips)
Some critical devices are not on a UPSAdd power strip after the UPS
Monitor, recorder, encoder, or LED processor without a video signalShow in diagram or Add HDMI splitter
No backup connection processor → screenChange processor
Monitor on stage fed over HDMI AOCAdd converter at monitor
A control room connection without a cable (e.g. deleted by hand)Reconnect
DMX fixtures in the scene but no console in the control roomAdd lighting console

Info items without a button suggest technical solutions: LED data over copper on a run longer than about 70 m (the limit is 100 m) is better sent over fiber with a converter at the screen, and microphone receivers more than 30 m from the stage call for remote antennas at the stage.

Weight, power, and supply

  • Put on a frame stand: the console or the total of devices exceeds the load capacity of a folding table.
  • Pick a larger UPS: the UPS is loaded above 80%.
  • Add 32 A 3-phase distribution board: the control room draw exceeds a 16 A outlet (2.9 kW with margin).
  • The switch PoE budget is smaller than the draw of the powered devices: add a PoE switch or PoE injectors.

Devices without a control room

After you delete only the footprint (Delete footprint, keep devices…), the devices go to the Devices without a control room group in the panel. The Rebuild control room button creates a new footprint around them facing the stage, and reassigns the devices and cables to it.

Did not find the answer?
Describe the problem and we will reply with a solution or add an article.