Every structure made with the wizard or the T tool has a Statics and support section in the inspector. Its summary (OK, Caution, Overload) is visible even when the section is collapsed. Results recalculate after every change to geometry, supports and loads.
What the app calculates
The structure is calculated as a beam grillage using the stiffness method, taking bending and torsion into account. A single run is a classic continuous beam. The app determines:
- the utilization of each span: the larger of moment / allowable moment and shear / allowable shear, from the series load table,
- span deflection in mm and as L/x,
- support reactions and the load on each point, tower and stand,
- hoist utilization against the WLL and tower utilization against the indicative capacity,
- outdoors: wind force, required ballast or guy line force (see Outdoor: wind, ballast and guy lines).
The app reads allowable loads from the series load table (UDL in kg/m, CPL in kg) and interpolates by moment between table rows. When lifting with hoists and GS, spans are calculated with a dynamic factor (1.2 by default), because manufacturer tables refer to static loads.
Thresholds and colors
| Utilization | Color in the editor | Statics status |
|---|---|---|
| up to 70 % | green | OK |
| 70–80 % | yellow-green | OK |
| 80–100 % | orange | Caution |
| over 100 % | red | Overload (error) |
The same 80 % threshold colors the bars in tables, the tiles and the labels in 3D. Deflection worse than L/200 gives a caution (the screen line may be uneven), worse than L/100 an error. The recommended maximum cantilever is 1.0 m for the 290 cross-section, 1.5 m for 400 and 2.0 m for 520.
Tiles and tables
The first level of the section is Rating with the capacity class name, the Points row and the tiles: Total mass, On points total or On towers total, Max span and Most loaded point. Below them you see at most two warnings; Show all notes reveals the rest.
The Spans and points section contains a span table (span length, utilization bar, deflection) and a support table (point class, hoist, bridle, position on the run, delete). Hovering over a table row highlights the span or point in 3D.
Warnings and fixes
Every warning says what is wrong and gives a number. Most have a fix button that changes the structure in a single undo step; the message after the fix has an Undo button. A fix that adds a support opens the structure editor with a support "ghost" at the suggested position: you can move it and confirm with the Add here button.
| Code | Level | When | Typical fixes |
|---|---|---|---|
span.over | error | Span over 100 % of capacity | Add a support in the span, Change cross-section to … |
span.warn | caution | Span at 80–100 % | Add a support |
span.outOfTable | error | Span longer than the series table | Add a support |
defl.warn / defl.over | caution / error | Deflection worse than L/200 / L/100 | Add a support |
cant.over | error | Cantilever longer than recommended | Move the point to the end |
point.over / point.near | error / caution | Point over 100 % / 80–100 % of WLL | Larger hoist, hoist next to it, spread over points |
point.limit | error | Overhead point limit exceeded | Hoist next to it, bridle, spread the load |
bridle.angle | error | Bridle angle over 120° | Lengthen the legs |
hoist.mixed | caution | Different hoists on one structure | Standardize on … |
hoist.c1 | error | C1 point without a C1 hoist | Change the hoist |
tower.over / tower.near | error / caution | Tower over 100 % / 80–100 % of capacity | Stronger cross-section, GS 400 |
tower.stability | caution (above 2 × threshold: error) | H/B above 3 | Base plate 0.8 m, Add outriggers |
tower.nonStd / tower.height | caution | Height cannot be built from sections / above recommended | Set … m |
stand.over / stand.span | error / caution | Stand overloaded / span over 6 m | Add stand |
support.none / support.unstable | error | No supports / supports do not hold the structure | Add supports automatically |
support.slack | error | Support does not carry load | Move or delete |
support.proposal | caution | Automatic layout suggests a different point arrangement | Apply suggestion |
run.nonStd / angle.nonStd | caution | Run cannot be built from sections / angle not in the series | Set … m, Align to …°, Use box corner |
outdoor.guy | error | Outdoor without guy lines or ballast | Add … ballast per tower |
wind.area / wind.stability | caution / info | Wind area, stability | Enter banners |
series.noTable / series.generic | caution / info | Series without a table / generic series | Enter manufacturer table |
load.unknownMass | caution | Equipment without mass | Enter the mass in the device data |
span.continuous | info | 3 or more supports on a run | Confirm the capacity over the supports with the manufacturer |
roof.docs | info | Stage roof | Roof system documentation |
model.v1 | info | Structure in the simplified model | Update structure model |
Advanced settings
The Advanced section lets you match the calculations to the equipment you actually have:
- Manufacturer table
- Rows: span, UDL (kg/m), CPL (kg).
Load from catalogcopies the class table as a starting point,Add rowadds another one. An empty table means the class model scaled by the series factor. Enter the values from the data sheet of your series here. - Lifting factor
- Uneven lifting with hoists, 1.25 by default.
- Cable allowance
- kg/m, when the cabling plan does not route cables along the truss.
- Dynamic factor
- Hoists and GS only: spans calculated with φ, 1.2 by default.
- Wind
Banners and mesh(m²); outdoors alsoWind speedandBallast per tower.- Support
Tower baseandOverhead point limit.- Manual loads
- Point loads or uniform loads on a run (see Loads).