Every structure made with the wizard or the T tool has a Statics and support section in the inspector. Its summary (OK, Caution, Overload) is visible even when the section is collapsed. Results recalculate after every change to geometry, supports and loads.

LED screen 520 kg · 4 × spot 36 kg86 %4.1 kN4.1 kN< 70 %70–90 %> 90 %
Spans colored by utilization, and support reactions.

What the app calculates

The structure is calculated as a beam grillage using the stiffness method, taking bending and torsion into account. A single run is a classic continuous beam. The app determines:

  • the utilization of each span: the larger of moment / allowable moment and shear / allowable shear, from the series load table,
  • span deflection in mm and as L/x,
  • support reactions and the load on each point, tower and stand,
  • hoist utilization against the WLL and tower utilization against the indicative capacity,
  • outdoors: wind force, required ballast or guy line force (see Outdoor: wind, ballast and guy lines).

The app reads allowable loads from the series load table (UDL in kg/m, CPL in kg) and interpolates by moment between table rows. When lifting with hoists and GS, spans are calculated with a dynamic factor (1.2 by default), because manufacturer tables refer to static loads.

Thresholds and colors

UtilizationColor in the editorStatics status
up to 70 %greenOK
70–80 %yellow-greenOK
80–100 %orangeCaution
over 100 %redOverload (error)

The same 80 % threshold colors the bars in tables, the tiles and the labels in 3D. Deflection worse than L/200 gives a caution (the screen line may be uneven), worse than L/100 an error. The recommended maximum cantilever is 1.0 m for the 290 cross-section, 1.5 m for 400 and 2.0 m for 520.

Tiles and tables

The first level of the section is Rating with the capacity class name, the Points row and the tiles: Total mass, On points total or On towers total, Max span and Most loaded point. Below them you see at most two warnings; Show all notes reveals the rest.

The Spans and points section contains a span table (span length, utilization bar, deflection) and a support table (point class, hoist, bridle, position on the run, delete). Hovering over a table row highlights the span or point in 3D.

Warnings and fixes

Every warning says what is wrong and gives a number. Most have a fix button that changes the structure in a single undo step; the message after the fix has an Undo button. A fix that adds a support opens the structure editor with a support "ghost" at the suggested position: you can move it and confirm with the Add here button.

CodeLevelWhenTypical fixes
span.overerrorSpan over 100 % of capacityAdd a support in the span, Change cross-section to …
span.warncautionSpan at 80–100 %Add a support
span.outOfTableerrorSpan longer than the series tableAdd a support
defl.warn / defl.overcaution / errorDeflection worse than L/200 / L/100Add a support
cant.overerrorCantilever longer than recommendedMove the point to the end
point.over / point.nearerror / cautionPoint over 100 % / 80–100 % of WLLLarger hoist, hoist next to it, spread over points
point.limiterrorOverhead point limit exceededHoist next to it, bridle, spread the load
bridle.angleerrorBridle angle over 120°Lengthen the legs
hoist.mixedcautionDifferent hoists on one structureStandardize on …
hoist.c1errorC1 point without a C1 hoistChange the hoist
tower.over / tower.nearerror / cautionTower over 100 % / 80–100 % of capacityStronger cross-section, GS 400
tower.stabilitycaution (above 2 × threshold: error)H/B above 3Base plate 0.8 m, Add outriggers
tower.nonStd / tower.heightcautionHeight cannot be built from sections / above recommendedSet … m
stand.over / stand.spanerror / cautionStand overloaded / span over 6 mAdd stand
support.none / support.unstableerrorNo supports / supports do not hold the structureAdd supports automatically
support.slackerrorSupport does not carry loadMove or delete
support.proposalcautionAutomatic layout suggests a different point arrangementApply suggestion
run.nonStd / angle.nonStdcautionRun cannot be built from sections / angle not in the seriesSet … m, Align to …°, Use box corner
outdoor.guyerrorOutdoor without guy lines or ballastAdd … ballast per tower
wind.area / wind.stabilitycaution / infoWind area, stabilityEnter banners
series.noTable / series.genericcaution / infoSeries without a table / generic seriesEnter manufacturer table
load.unknownMasscautionEquipment without massEnter the mass in the device data
span.continuousinfo3 or more supports on a runConfirm the capacity over the supports with the manufacturer
roof.docsinfoStage roofRoof system documentation
model.v1infoStructure in the simplified modelUpdate structure model

Advanced settings

The Advanced section lets you match the calculations to the equipment you actually have:

Manufacturer table
Rows: span, UDL (kg/m), CPL (kg). Load from catalog copies the class table as a starting point, Add row adds another one. An empty table means the class model scaled by the series factor. Enter the values from the data sheet of your series here.
Lifting factor
Uneven lifting with hoists, 1.25 by default.
Cable allowance
kg/m, when the cabling plan does not route cables along the truss.
Dynamic factor
Hoists and GS only: spans calculated with φ, 1.2 by default.