Each structure has one support mode: Hoists, Towers, Stands or Ground support. You choose the mode in the wizard or in the inspector, in the Structure → Support section. The app places the supports by itself, and you can then move, add and delete them.
Automatic and manual layout
The Points row in the Statics and support section tells you where the support layout comes from:
- Automatic (unsaved)
- A layout calculated automatically on every load change.
- Automatic
- An automatic layout saved in the project. It does not change by itself when you attach equipment; when the app finds a better layout, it shows the note "Automatic layout suggests a different point arrangement" with the
Apply suggestionbutton. - Manual
- A layout changed by hand. The app does not move the points.
Buttons under the warnings: Add hoist (or Add tower, Add stand, Add GS tower, depending on the mode) inserts a support in the middle of the most utilized span. Select hoists matches the hoists to the current loads.
Hoists and point classes
The catalog has separate D8 and D8+ hoists (250, 500, 1000 and 2000 kg) and C1 hoists (500 and 1000 kg). The capacity is given directly for the hoist class. You set the class of each point in the point table with the Point class field.
| Point class | Allowed hoists | Notes |
|---|---|---|
| D8 | Any | Default class. |
| D8+ | D8+ or C1; D8 only as derated | A D8 hoist at a D8+ point counts with half its rated capacity. The Above audience switch sets D8+ at all points. |
| C1 | C1 only | Neither D8 nor D8+ meets C1. Such a choice gives the error "… in class C1 requires a C1 hoist". |
The Hoist field has a Select automatically item (the current choice is shown in brackets) and a list of hoists: first those suitable for the point class, then the rest.
How hoists are selected automatically
The point load is the support reaction multiplied by the uneven lifting factor (1.25 by default) plus the hoist body mass, the chain mass and the point hardware (slings, shackles, steel). The chain is counted for the height of the overhead point plus 2 m. The app picks the smallest hoist of the point class at which the load stays within 80 % of the WLL.
On one structure the app uses one model, because different hoists have different lifting speeds. When the project contains different models, a note about the truss tilting appears with the fix Standardize on ….
| WLL utilization | Status |
|---|---|
| up to 80 % | OK |
| 80–100 % | Caution: "Point …: … WLL." with a fix to change to a larger hoist |
| over 100 % | Error: "Point …: … kg on hoist … (WLL …)." with fixes: larger hoist, hoist next to it, spreading the load over several points |
Bridles and the overhead point limit
In the point table, the Bridle switch adds two legs from the point to two overhead points. Once it is on, you enter the bridle angle, and below you see the force in the leg and its multiple of the load. An angle above 120° gives an error with a suggestion to lengthen the legs.
In the Advanced → Support section, enter the Overhead point limit from the venue documentation (0 means no limit). Exceeding the limit gives an error with fixes: adding a hoist next to it, a bridle to two overhead points, or spreading the load over several points. With a bridle, the message also gives the horizontal component at the anchor.
A point that lands on a section joint gets the note "Point … lands on a joint." with a suggestion to move it by 0.25 m.
Towers and ground support
A tower splits the run with a node. The bottom chord height must be built from tower sections; otherwise a note appears with the Set … m button. The app compares the tower load with the indicative capacity of the tower type (tower on a base plate or GS of a given cross-section): above 80 % there is a caution, above 100 % an error with a suggestion of a stronger cross-section or GS 400.
Tower slenderness is the ratio of the bottom chord height to the base width (H/B). Above 3 the app warns, above 6 it reports an error. The fixes are Base plate 0.8 m or Add outriggers. You can also change the base by hand in the Tower base field.
Stands
The Stands mode picks a crank-up stand for the load and height. The stand load should not exceed 80 % of its capacity and must act centrally. For the 290 cross-section, a span between stands above 6 m gives a note with the Add stand fix.
Supports that do not carry load
The statics take into account that supports work in one direction only. A chain does not push, and a structure can lift off a tower. If a point does not carry load, the error "Slack chain at point …" appears and the layout is calculated without that point. The fix moves or removes such a point.
A structure without supports has the error "The structure has no supports.", and a layout that does not hold it has the error "The supports do not hold the structure". In both cases the Add supports automatically button restores the automatic layout.