StageDesigner

Recalculate all and warning fixes

What the Recalculate all button does, in what order the planner fixes the plan, what is left for a human decision and which fix buttons each warning has.

4 min read
Documentation contents ▾

Recalculate all on the Cabling panel toolbar plans the cabling again with the current rules, then runs the fix loop. The goal: a plan without the errors and warnings the planner can remove on its own. The same loop runs after the wizard and after a power connection change.

Order of fixes

The loop starts with causes and ends with effects:

  1. Outdated routes (voltage drops and bundles are calculated on routes).
  2. Power connection: a generator is sized automatically. The planner does not change the venue's power connection.
  3. Distribution boards: sockets, input current, protection, control room load.
  4. Circuits and phases: splitting circuits, balancing phases, leakage behind RCDs.
  5. Cross-sections: batch selection of larger cross-sections for current-carrying capacity, voltage drop and fault loop.
  6. Routes: corridors, exits, no-cable zones, separating bundles.
  7. Signals: DMX, LED data, signal lengths.

A fix is only kept if it improves the result. The plan state is never worse than the best one reached along the way. The loop is limited to 40 steps and approx. 12 seconds. The progress bar first shows Planning routes, then Selecting cross-sections, phases and distribution boards.

The only distribution boards the loop can move are those added by the planner. Distribution boards placed by hand, locked ones and those belonging to the control room stay in place.

Recalculation result

The toast summarizes the changes, e.g. "Cabling recalculated: 363 cables · cross-sections selected (12) · phases balanced (7 distribution boards) · needs decision: 2". Possible items: selected cross-sections, balanced phases, added and moved distribution boards, split circuits, separated routes. You undo all of it in one step.

Needs decision

If issues remain after recalculation, the heading Needs decision (N) appears above the list: cross-sections, phases and distribution boards are already selected, and these issues need a human decision. An issue may have a note on what the planner checked.

ReasonWhat is left to decide
Venue power connectionThe planner does not change the venue's power connection, because it is venue data. To decide: a larger power connection, if the venue has one, or a generator.
Manual settingA locked cable, one with a manual length or cross-section, or a distribution board not placed by the planner.
Voltage drop or fault loop not improvedThe planner tried a larger cross-section, moving the distribution board, splitting circuits, an extra distribution board and feeding from a closer distribution board. To decide: a power connection or generator closer to the loads, a distribution board at the structure, or accepting the drop up to the error threshold.
Current-carrying capacity not improvedTo decide: a separate route for some of the cables, or a larger cross-section cable set by hand.
Distribution board or phases not improvedTo decide: moving some of the loads or a larger distribution board.
Warning without a fixE.g. a missing DMX terminator: you add it on site.

One-click fixes

You can also fix each issue individually with the button next to it. The Show, Show structure and Create control room buttons do not change anything in the plan: they highlight cables, open the structure or open the control room wizard.

ButtonWhat it does
Split circuitSplits the circuit in two.
Balance phasesRearranges unlocked circuits across the phases.
Change cross-sectionA larger cross-section in the same connector system for the indicated cables.
Separate cablesNew routes next to the power bundle.
Move distribution boardMoves the planner's distribution board closer to the loads.
Add distribution board, Recalculate power, Replace distribution boardRecalculate power with new or replaced distribution boards.
Change power connectionSets the minimum power connection for the phase currents and plans power again.
Recalculate route, Recalculate routesNew planner routes for the indicated cables.
Split line, Recalculate addresses, Recalculate DMX, Add nodeDMX fixes, described in DMX patch.
Recalculate ports, Add processor, Remove extra cablesLED data fixes.
Connect automaticallyAdds missing connections (fixtures and screens without power or DMX).
Fit lengthRemoves a manual length that is shorter than the route.
Change cable typeA type with a longer allowed signal length.
Delete cableDeletes a cable with no device at its end.
Did not find the answer?
Describe the problem and we will reply with a solution or add an article.