Where to find it
Open the Venue Layout Plan (⌘ 1) and choose the Lighting section in the Stage group. The list shows Truss runs with length, role relative to the stage (in front of the stage, above the stage, behind the stage, beside the stage), fixture count and load. A run with exceeded capacity is marked.
No structure: front truss
When the scene has no structure, the section offers a front truss above the stage. Choose the Type (Truss 290 mm or Truss 400 mm) and click Add front truss … m above stage. The truss length and height are matched to the stage so that the front light hits faces at an angle of about 45°. The truss always stands in front of the stage front edge.
Quick sets
The Quick Sets section suggests typical lighting tasks for the structure in the scene. Each set has a description with the reasoning and an Insert N button. When there is no suitable truss, you see the reason instead of the button.
| Set | Fixtures and rule |
|---|---|
Front light | Profile heads every 1.5 m on the truss in front of the stage, aimed at face height (1.7 m above the stage floor). The description gives the vertical angle and warns when it is too flat (below 35°) or too steep (above 60°). Recommended 40–50°. |
Backlight | Wash every 2 m on the truss behind or above the stage. The outline separates the performers from the background. |
Sides | 2 Profile heads per side on the runs beside the stage. They model the silhouette and fill the shadows from the front. |
Stage wash | Wash every 2.5 m above the stage (or in front of it): even color coverage of the stage floor. |
Audience effects | Beams every 1.5 m at the back of the stage, aimed 2.5 m above the audience floor. |
The rules are rules of thumb and approximate. Front light follows the McCandless method: the cones of neighboring fixtures overlap, and an angle of about 45° gives natural light on faces. The lighting designer always makes the final decision.
Distribute fixtures on truss
- Click
Distribute fixtures on trusson the section bar. - Click a run on the plan or in the list. Further clicks add more runs.
- Set the
Model,Directionand layout options (described below). - Check the preview: the fixture count,
Weight with riggingandStructure load. Warnings appear below. - Click
Insert N fixtures.
Model- A fixture from the library (all types except the followspot).
DirectionTo stage,Down,To audienceorSymmetric.Every other flipped- Every other fixture rotated by 180°.
ByCount(theCount per runfield, 1–64) orSpacing(theSpacingfield in meters).AlignmentFrom nodes: the first and last fixture at the margin from the nodes.From center: the block of fixtures centered on the run.Node margin- Distance from the nodes in meters.
Fixture groups
Each inserted set and each distribution creates a fixture group, shown in the Fixture Groups list with its color, count and model. When you choose a group, the panel shows Fixtures, Weight with rigging and Structure utilization.
Layout: the same fields as when inserting, plusGroup color. Changing the parameters rearranges the group fixtures.DMX: the fixture DMXMode, theManual addressestoggle with theUniverseandStart addressfields. Without manual addresses, the cabling plan assigns addresses along the truss.- You rename the group in its header and delete the group with the trash icon.
Addressing is described in DMX addressing, and cable routes in Cabling plan. The plan also shows stands with their fixture count, capacity utilization and ballast.