StageDesigner

Position, direction, and zone on the plan

Where the control room goes: automatically on the stage axis or at a point you pick, facing any direction. On the venue layout plan it gets an exclusion zone that audience seating avoids.

4 min read
Documentation contents ▾

Position in the wizard

In the Layout step, the Position group has two modes:

Automatic
The control room stands on the stage axis, facing the stage. Distance from stage has an automatic value with the recommended range for the event type; after you type your own, the reset button returns to automatic.
Pick in scene
The wizard window hides and you click the floor where the control room should be (Esc cancels). The control room is centered on that point, facing the stage. Pick again lets you correct the point.

The automation avoids obstacles. When audience seating, an aisle, or another object stands on the axis closer to the stage, the control room moves further back, and the wizard explains the shift in a message below the mini floor plan. When the project has no stage built from decks, the stage front is assumed to be in front of the screens, and without screens at point 0.

Distance and sound delay

The From stage readout measures the distance from the front edge of the control room to the stage front. Sound delay is that distance times 2.9 ms/m, that is how much later the sound from the PA at the stage reaches the engineer’s position.

Moving after applying

In the control room card (Position and riser section) and in the inspector you have Distance from stage and the Center on stage axis button. Changing the distance moves the control room along the axis; the rotation stays the same.

Direction: toward the stage or any angle

The Direction row has an automatic "Toward stage" mode (Auto badge) and a manual mode with an angle relative to the stage axis. Quick values: 0° straight ahead, 90° and 270° sideways, 180° backward. The field accepts any angle; the arrows change it in 15° steps.

The rotation is rigid around the center of the footprint: the tables, riser, steps, barrier, devices, and control room cables all rotate together. Cable routes to the stage recalculate on their own. Restoring automatic mode turns the control room back to face the stage.

The control room on the venue layout plan

The venue layout plan shows the control room footprint with a direction arrow, name, and angle. Clicking the footprint selects the control room; the section column shows the Direction and position group with the Direction row, the distance from the stage, and the deviation from the direction toward the stage.

Drag the footprint
Moves the control room (in "Toward stage" mode it also turns it toward the stage)
Drag the handle in front of the control room
Rotates in 1° steps
Shift+drag the handle
Rotates in 15° steps relative to the stage axis

Changes made on the plan go straight to the 3D scene as one undo step. You change the devices, event type, and riser in the Control room panel. You do not copy a control room on the plan: add another one with the wizard.

Control room zone: audience seating avoids it

The Add an exclusion zone in the venue layout plan option in the Summary step creates a "Control room" exclusion zone with the Technical (e.g. FOH) purpose on the first plan of the project. The zone is the control room footprint enlarged by 1 m on each side, rotated the same way as the control room.

  • Tables are not placed in the zone, and audience blocks skip seats in the zone and within 0.3 m of its edge. The block description then shows the number of seats "skipped in zones".
  • The zone moves and rotates together with the control room. In the Exclusion zones section, the Select control room button goes from the selected zone to its control room.
  • A project without a venue layout plan does not need the zone, so the option is inactive then.
Did not find the answer?
Describe the problem and we will reply with a solution or add an article.