StageDesigner

Stage barriers and stair railings

The Auto, Always, and None barrier modes, a stage accessible to the audience, the performance edge, open sides against a wall, and railings at the stairs.

3 min read
Documentation contents ▾

Every stage has a Barriers section in the inspector. The app determines the edges that need protection, places barrier modules on them, and calculates the parts list. Edges at the stairs and edges marked as the performance edge stay open.

Barrier modes

ModeWhat it does
AutoBarriers appear when the stage height exceeds the edge threshold. The default threshold is 1.0 m, and 0.5 m for a stage accessible to the audience. Stair railings from 0.5 m.
AlwaysBarriers on the edges and stair railings regardless of height.
NoneNo barriers. When the height requires protection, the inspector shows a notice with the Add barriers button.

You set the mode for new stages in Defaults for new → Barriers. You change the edge threshold in the Safety → Rules section (Barrier from stage height).

Stage accessible to the audience

The Stage accessible to the audience switch lowers the barrier threshold from 1.0 m to 0.5 m. Turn it on when guests come up on stage: an awards ceremony, a contest, a first dance on the riser.

Performance edge

The Performance edge field indicates the side of the stage where the artists perform: Plan top, Plan bottom, Plan right, Plan left, or None (barrier all around). That edge stays without a barrier; the app reminds you to mark it with contrasting tape.

Sides without a barrier

When barriers are on, the No barrier row lets you leave sides open: Top, Bottom, Left, Right. This is for a stage pushed up against a wall or a built structure. When an open side needs protection, the inspector shows how many meters stay without a barrier, with a note that an open side is acceptable only against a wall or a built structure.

Railings at the stairs

With barriers on and a stage with stairs, the Railings at stairs switch appears: a 1.1 m handrail on both sides of the run. It is on by default. When the stage is higher than 0.5 m and the stairs have no railings, the run inspector shows a notice.

Parts list

Below the settings you see the barrier modules (2 m, 1 m, and 0.5 m with quantities) and the number of stair railings. The section summary gives the barrier length in running meters. Barriers are 1.1 m high with a 0.15 m toe board; after the plan is applied they stand in the 3D scene together with the decks.

Did not find the answer?