Safety: evacuation, aisles, visibility, and capacity

The Safety section calculates access to exits, exit and aisle widths, screen visibility, and an estimated venue capacity. All of it is indicative and must be verified by an expert.

3 min read
Documentation contents ▾

The Safety section is in the Check group. The counter next to it shows the number of problems to review. The Evacuation: … problems badge in the plan footer takes you straight to this section.

Evacuation

The analysis requires the venue walls and doors. Without them, the section asks you to draw the outline. When the walls do not form a closed outline, an error appears with the Recalculate button.

People in calculation
The number of people from the seats in the plan.
Exit width
The total width of the exits compared with the required width.
Longest travel distance
The longest route from a seat to an exit compared with the limit.
Seats without access
Seats from which there is no route to an exit.
Travel distance too long
Seats with a travel distance longer than the limit.

The problem list describes each case, for example no exits, a single exit for a large number of people, an exit that is too narrow, or a narrow aisle for a large flow. Clicking a problem centers the plan on its location and turns on the evacuation overlay. The Exits list shows each exit with its width and the number of people assigned to it; automatically detected exits are labeled as such.

The section tool buttons turn on the overlays: Evacuation on plan, Screen visibility, and Aisle clearances.

Other checks

The problem list also covers stages without required barriers, stairs without railings and with incorrect geometry, deck load capacity, the clearance between audience rows, event fencing in the crowd zone at the stage, and the horizontal load on the barrier in front of the stage.

Screen visibility

For the screens in the scene, the app rates every seat: Seats rated, Outside the good visibility zone, and Bottom of screen blocked. The good visibility zone lies between 1.5 and 8 screen heights (up to 6 for text), within ±45° of the screen axis. The Show zones on plan switch draws the zones on the floor plan.

Venue capacity

The seat breakdown in the plan: at tables, audience seating, wheelchair spaces, chillout, standing at cocktail tables and at bar counters, plus the gross and net area. The same total is in the plan footer under the Seats button.

SetupNet area per personNotes
Theater0.6–0.8 m²Rows of chairs without tables, aisles between sectors
Classroom1.4–1.8 m²Rectangular tables in rows, chairs at the front
Banquet1.2–1.5 m²Round tables Ø1.8 m for 8–10 people
Cabaret1.4–1.7 m²Round tables, chairs on the room side
Cocktail0.5–0.7 m²Standing, high tables

The Estimate by net area block converts these densities into a range of people for the current venue. It is a quick guide at the quote stage; the binding figure is the permitted number of people from the venue documentation.

Rules

The Rules section collects the thresholds the analysis uses. After you change any value, the rules have the Custom status, and the Restore typical button returns to the defaults.

RuleDefault value
Minimum aisle width1.2 m
Main aisle1.4 m
Clearance between rows0.45 m
Seats to an aisle on one side15
Seats to an aisle on both sides30
Escape travel distance40 m
Exit width per 100 people0.6 m
Minimum exit width0.9 m
Barrier from stage height1.0 m
Did not find the answer?