StageDesigner

Tables, riser, and barrier

Table rows, riser height calculated from the sightline over the audience, steps, and a barrier. Devices on the riser change height together with it.

3 min read
Documentation contents ▾

The control room layout picks the furniture on its own: tables in one or two rows, a riser under the tables, stools, racks, camera tripods, and steps. You decide the number of rows, the riser height, and the barrier. The same settings are in the wizard’s Layout step, in the control room card in the panel (Position and riser section), and in the control room inspector.

Table rows

Table rows switches between 1 row and 2 rows. A concert starts with two rows, the other types with one. With two rows, Back row riser appears: by default 0.4 m higher than the front, so operators at the back can see the stage over the heads of the people in front.

The number of tables follows from the length of the devices in a row. When the tabletops run out of space, the analysis shows a warning that the row is too short.

Riser height

You choose the riser from a list: No riser, 0.2 m, 0.4 m, 0.6 m, or 0.8 m (modules in 0.2 m steps). The Auto item applies the height recommended from the sightline and explains what it is based on.

How the sightline is calculated

The operator must see a point 1.0 m above the stage floor over the heads of the nearest audience members. The app assumes:

QuantityValue
Head of a seated / standing audience member1.20 m / 1.70 m
Clearance above the head0.12 m
Distance from the operator to the nearest head1.5 m
Operator eye height on a chair / stool / standing1.20 m / 1.55 m / 1.65 m
Operator postureconcert standing, gala on stools, others on chairs

The result is rounded up to the 0.2 m module (with a 2 cm tolerance) and capped at 0.8 m. Changing the audience from seated to standing, the distance from the stage, or the stage height changes the recommended height. When the riser is lower than recommended, the analysis shows a warning with the Set … m fix.

Steps and barrier

A riser higher than 0.5 m (in practice from 0.6 m) automatically gets steps at the back of the control room. The wizard then reminds you to protect the edges with a 1.1 m barrier. Without a barrier, the analysis reports a notice with the Add barrier fix.

The Barrier around the control room switch is in the wizard options, in the control room card, and in the Options section of the inspector. The barrier separates the position from the audience even on a low riser, which helps with a standing audience.

Devices move with the riser

Changing the riser height repositions the tables and the devices placed by the layout. Devices placed by hand (which Rearrange does not move) also change height by as much as the riser they stand on was raised or lowered. With two rows, devices in the back part of the footprint follow the back riser. This way a console moved by hand does not end up below the tabletop after the riser goes up.

Elements no longer needed after a change disappear on their own: the riser at height 0, the barrier when switched off, steps on a low riser, a tripod without a camera.

Rearrange

The Rearrange button in the control room card (and in the Actions section of the inspector) lays out the tables and devices again according to the current set. Devices moved by hand stay in place. Every change to the riser, rows, or barrier is one undo step.

Did not find the answer?