StageDesigner

Loudspeaker set in the inspector: angles, tilt, delay

Settings of the selected set: model, role, number of elements, mounting, sub arrangement, L/R pair, angles between array elements with the automatic Set angles, height, gain and delay.

3 min read
Documentation contents ▾

Select a set in the scene or in the list on the System tab. The inspector shows the sections Loudspeaker set, Angles and tilt (array) or Tilt and height (single loudspeaker), Level and delay and Notes. Every change is a single undo step.

Loudspeaker set

Model
Loudspeaker class from the library.
Role
Main, Subwoofer, Front fill, Out fill, Delay, Monitor, Fill. The role affects the recommended delay and the contribution to the acoustics map (monitors are not part of the audience field).
Number of elements
For an array, the caption shows how many elements the class frame allows.
Mounting
Flown, Ground, On stand, Stacked.
Sub arrangement
For subwoofers: Omni, Cardioid (every third reversed, delayed and polarity inverted), End-fire (on axis every 1 m, 2.9 ms delay per element).
Muted
Excludes the set from the calculations without removing it from the scene.

The L/R pair group shows the other side and the Mirror pair changes switch: a change on one side is carried over to the other right away. A set without a pair has the Create L/R pair action. The Data group shows the mass with frame, the hanging location (a structure with statics or "Point outside structure") and the class throw.

Array angles and tilt

For an array you set Top element tilt, Hanging point (with a caption showing the height of the array bottom) and the angles between consecutive elements (Angle 1–2, Angle 2–3…). For a single loudspeaker: Tilt and Base above floor.

  1. Set the hanging point height.
  2. Click Set angles in the group header.
  3. Check the coverage fan in the scene (System tab, Array coverage fan in scene switch).
  4. Adjust individual angles by hand; an automatic value has an Auto badge and can be restored.

How Set angles works

The automatic setting uses the equal energy over distance method: the top element aims at the last row at ear height, the bottom one at the first row, and the angles grow toward the bottom (small for long-throw elements, larger for near ones). Angles are clipped to the class frame range and rounded to 0.5°. Angles outside the frame range give a note with the Set angles fix; too many elements in an array give an error with the Reduce number of elements fix.

Level and delay

Gain
Level change of the set in dB relative to the system operating level.
Delay
In ms. For delays the automatic value is the distance from the arrays / 343 m/s + 7 ms; for front fills and other sets, alignment to the arrays at a point 3 m in front of the set.
Amplifier channels
Channel assignment from the system analysis.
Cables
A cable from the plan (with its code) or an estimate: length, cross-section and loss in dB.
Did not find the answer?
Describe the problem and we will reply with a solution or add an article.