Room reverberation determines speech intelligibility. The app calculates it from the room volume and surface areas and the selected materials. The settings are saved in the project and work even before you add loudspeakers.
Where the app gets the room from
The volume and surfaces come from the wall outline of the venue layout plan (or from the floor of the "Room" environment) and from the room height. Windows, doors and backstage drapes count as separate surfaces. When there are no walls, the app can assume a room from the listening zone envelope plus 3 m, or treat the event as outdoor, without a reverberant field.
The Room height field works automatically when no value is entered. A value entered by hand has a button to restore the automatic value. Outdoors, the Reverberation section shows the note "Outdoor: no reverberant field. Enter the room height if the event is indoors."
Materials
The Materials group has a separate choice for the floor, walls and ceiling. The hint next to each list item gives the absorption coefficient α at 500 Hz and a short description.
| Surface | Example materials in the app |
|---|---|
| Floor | Concrete, terrazzo; Tiles, stone; Parquet, boards; Thin carpet; Thick carpet with underlay; Stage deck; Grass, ground |
| Walls | Plaster on masonry; Painted blocks; Plasterboard on frame; Glass; Wood paneling; Light curtain; Heavy pleated drape; Acoustic panels; Tent (PVC tarpaulin); Trapezoidal sheet metal (hall) |
| Ceiling | Plaster on masonry; Plasterboard on frame; Wood paneling; Acoustic panels; Acoustic suspended ceiling; Tent (PVC tarpaulin); Trapezoidal sheet metal (hall); Concrete |
The coefficients come from published tables for the 125 Hz–4 kHz bands; the 63 Hz and 8 kHz bands are extrapolated. Specific products may differ. Audience absorption is calculated from the number of people.
Room and levels
- Room height
- Automatic from the plan or entered by hand.
- Ear height
Seated 1.2 morStanding 1.6 m. The same value is used for the automatic array angles.- Temperature and Humidity
- Affect air absorption. 20 °C and 50 % by default.
- Background noise
- Background noise level in dB(A), 42 dB(A) by default; recommended range 25–50 dB(A). Affects STI.
- Target level
- LAeq in the listening zone; the sound system wizard enters the operating level of its proposal here.
- Subs: phase summation at 63 and 125 Hz
- Takes into account the path, delay and polarity of the subs, which reflects how cardioid and end-fire arrangements work.
Reverberation
The Reverberation section shows RT60 (500 Hz–1 kHz), average C80 / C50, Volume with the number of people, and the By band table. The reverberation time is calculated with the Sabine and Eyring formulas including air absorption, and the reverberant field and the C50 and C80 indicators with the Barron revised theory.
When T (500–1000 Hz) exceeds the value recommended for speech per DIN 18041 (group A2) by more than 20 %, or the average STI drops below 0.5, the Long reverberation note appears with the Change materials fix, which sets a heavy pleated drape on the walls. With STI below 0.45 the note has error level.
Recommended delays
The Delays section shows the current and recommended value for each support set (front fill, out fill, delay). The recommended delay is the median difference between the arrival time of main and of the set in the area where the set dominates, plus 7 ms (precedence effect, range 5–10 ms). The Set button enters the recommended value. A difference greater than 3 ms (10 ms for sets that do not dominate anywhere) gives the note Delay: set name.