StageDesigner

Sound and acoustics report

The project report sections Sound system: equipment and Sound system: acoustics: sets with angles, masses, amplifiers, cables with losses, SPL and STI maps, reverberation tables, a method description with standards and the procedure for verification measurements.

3 min read
Documentation contents ▾

The project report has two sound sections. The numbers in the report come from the same analysis as the Sound panel, so the report matches what you see in the app.

ProjectProject report… (⌘ ⇧ E / Ctrl + Shift + E)

You can also open the report from the panel: Sound report on the System tab and Acoustics report on the Acoustics tab open the report directly at the right section.

Sound system: equipment

  • sets with role, model, number of elements, tilt and angles,
  • masses with frames and rigging loads,
  • amplifiers with channel assignment,
  • loudspeaker cables with length, cross-section and loss,
  • system warnings.

Sound system: acoustics

  • SPL A (LAeq) map at the target level and STI map in plan view, with the ear height and background noise level stated,
  • reverberation and indicator tables,
  • recommended delays,
  • a method description with a list of standards and sources,
  • an on-site verification measurement procedure.

Standards and sources cited in the method description

The report lists the documents the calculation method is based on. The app does not claim compliance with them.

  • PN-EN ISO 3382-1 and PN-EN ISO 3382-2: measurement of room acoustic parameters (T, C50, C80, reverberation time),
  • IEC 60268-16: objective rating of speech intelligibility by the STI index,
  • PN-ISO 9613-1: absorption of sound by the atmosphere,
  • IEC 61672-1: sound level meters (A-weighting),
  • the Sabine and Eyring reverberation time formulas, the Barron revised theory,
  • DIN 18041: recommended reverberation time,
  • the WHO guideline for safe listening at events: 100 dB(A) LAeq 15 min,
  • the Polish regulation on occupational exposure limits (NDS and NDN): noise NDN 85 dB(A) for 8 h.

On-site verification measurements

The report includes a procedure for checking the simulation in the room:

  1. Reverberation time per PN-EN ISO 3382-2: several source and microphone positions, octave bands 125 Hz–4 kHz, room in its in-use state.
  2. Signal: interrupted pink noise or an exponential sine sweep (from the impulse response you determine T, C50, C80 and STI).
  3. Class 1 sound level meter with a calibrator, calibration before and after the measurements, microphone at ear height (1.2 m seated, 1.6 m standing).
  4. Level distribution: pink noise from the system on a grid of points in the zone, compared with the map (deviation ±3 dB).
  5. During the event: continuous measurement of LAeq 15 min and LCpeak at the control room and at the loudest spot in the audience area.

Export

You save the report as PDF or CSV from the report window. Every page has a footer with a disclaimer about the nature of the values. You can turn off the acoustics section if the report should cover only the equipment.

Did not find the answer?
Describe the problem and we will reply with a solution or add an article.