The patch is a list of fixtures with universe, start address and channel count. The planner proposes it together with the DMX lines, and you can change any address. The patch is in the DMX tab of the Cabling panel, in the Patch group.
Patch table
Columns: device (with mode name), line, universe, address, channel count. Rows are sorted by universe and address. The group description reminds you that the fixtures' DMX modes are examples and the channel footprint must be checked in the device manual.
Changing an address by hand
- Open the
DMXtab in the Cabling panel. - In the patch table, type the new address in the fixture's field. The field accepts values that keep the fixture within 512 channels.
- The address gets a padlock "Address set manually". It stays unchanged when addresses are recalculated.
If the new address overlaps another fixture in the same universe, the message "Overlaps: …" appears below the field, and the issue list shows an error with the Recalculate addresses fix.
Recalculate addresses
Recalculate addresses reassigns addresses on all lines without changing cables. Manual entries stay. The address overlap fix from the issue list may release the manual address of a conflicting fixture; the toast then says how many entries lost their manual address and whether any overlaps are left for a manual decision.
The Readable addresses toggle in the Patch group recalculates addresses immediately: on gives type blocks starting at full hundreds, off gives consecutive addresses.
Splitting a line
Split line next to a line in the table (or the fix on a warning) splits the chain in half. The second half gets a new universe, a separate source output and addresses from 1. The cable between the halves now starts at the source, and both lines end with a terminator. The button is inactive for a line with one fixture.
DMX warnings
| Warning | When | Fix |
|---|---|---|
| Line has too many devices (error) | More than 32 devices on a line. | Split line |
| Line too long | Total cable length of the line above 300 m. | Split line |
| No terminator | Line without a 120 Ω DMX terminator at the end. | none (add a terminator) |
| Universes from one output (error) | Two universes come out of one DMX output. | Add node |
| Universe has too many channels (error) | Total channels or the end of the last fixture above 512. | Recalculate addresses |
| Addresses overlap (error) | The ranges of two fixtures in the same universe overlap. | Recalculate addresses |
| Fixture in the wrong universe for its line (error) | The fixture's address is in a different universe than the line it hangs on. It will not receive data. | Recalculate DMX |
| Fixtures without DMX control | The fixture cannot be reached by DMX cables from a node or console. | Connect automatically |